What Information Should Be Included In A Fire Rated Glass RFQ
What Information Should Be Included In A Fire Rated Glass RFQ
A clear and complete RFQ (Request for Quotation) for fire rated glass ensures accurate pricing, correct specifications, and reduces project risks. Buyers should provide all relevant information about fire rating, dimensions, frame system, hardware, installation conditions, and delivery requirements.
Get QuoteWhy Complete RFQ Information Is Critical
Incomplete RFQs often lead to inaccurate quotations, delays in production, and costly rework. Fire rated glass performance depends on proper fire rating, glass structure, frame system, door hardware, installation conditions, and shipping arrangements. Providing full details upfront allows suppliers to recommend the right solution.
1. Required Fire Rating
Specify the required fire rating according to local building codes and project needs. Common ratings include EI30, EI60, EI90, and EI120.
EI30: low-risk internal partitions
EI60: offices, corridors, standard commercial areas
EI90: staircases, escape routes, public buildings
EI120: data centers, electrical rooms, critical fire zones

2. Glass Size, Thickness, And Panel Layout
Provide precise measurements, including width, height, thickness, and layout of each panel. Indicate any oversized panels, irregular shapes, or special design features.
3. Frame System And Seal Details
Specify the type of frame (steel, aluminum, or frameless), frame profile, glazing beads, gaskets, and fireproof seals required. Clarify whether the RFQ should include the complete system or only the glass panels.
4. Door Hardware And Accessories
If the RFQ includes fire rated glass doors, include details about door closers, hinges, locks, handles, panic bars, and access control systems. Hardware compatibility affects fire performance and installation.
5. Installation Conditions And Site Information
Describe the wall type, floor and ceiling levels, access for panel handling, site constraints, and any renovation conditions. This helps the supplier evaluate feasibility and plan for custom support if needed.
6. Delivery And Packaging Requirements
Include delivery location, expected schedule, required export packaging (reinforced crates, corner protection, moisture control), and labeling instructions. This ensures panels arrive safely and ready for installation.

RFQ Checklist Summary
Required fire rating: EI30, EI60, EI90, EI120
Glass panel dimensions, thickness, and layout
Frame type, profile, glazing beads, gaskets, seals
Door hardware: closers, hinges, locks, handles, panic bars
Installation conditions and site access
Special panel requirements (oversized, irregular, tinted, etc.)
Export packaging and delivery instructions
Project drawings, floor plans, and elevation sections
Quantity and installation sequence
Contact details and RFQ reference number
Conclusion
Providing complete and accurate information in a fire rated glass RFQ reduces errors, ensures accurate quotations, and helps suppliers propose solutions that meet fire rating, frame system, and project requirements. Buyers should include all the above details to avoid delays and extra costs.